GE Refrigerator Fan Motor Diagnostics
This GE refrigerator fan motor guide is for GE's electronic refrigerators fabricated later 2002. Including top-freezers, bottom-freezers, and side-by-side models.
This page will walk y'all through refrigerator fan motor diagnostics for GE electronic refrigerators. The chief board controls the fan motors on these refrigerators. This makes them more difficult to check just with the help of this page it is easy. On GE electronic refrigerators the master board is located on the dorsum of the refrigerator. There is an access console either on the bottom right or the top left of the back of the fridge.
Note that not all GE refrigerators made afterwards 2002 are electronic models then if at that place isn't a main board, your refrigerator isn't an electronic refrigerator and this page doesn't utilize to your refrigerator. However, if y'all have an electronic lath and the fan motor isn't running this page volition help.
Note that if you at someday determine that the master board is bad wait closely at the board for any burnt resistors. If yous see a burnt resistor replace the fan that isn't working along with the board because the fan near likely caused the board to go bad. And so if you only replace the main board the fan will cause the new board to go bad as well. That being said, (brunt resistor or non) the safest road is to replace both the fan and the lath.
Main lath replacement tip-Step #two on the installation instructions says to eliminate thermistor jumper wire, read that step carefully. Information technology is only necessary on lesser freezers and encoder models. In that location is a list of serial number prefixes. What this means is that if your refrigerator is an encoder model and the first three messages of the serial number begin with 1 of the listed prefixes, then you take to cutting out the jumper as described. An encoder model is a model with turn-dial controls rather than button or digital.
Below is a motion-picture show of a main board for a GE electronic refrigerator. It shows the location of the J2 plug where testing for fan motors is done. Note that the location of the J2 plug may vary depending on the year the refrigerator was made. Too the board may be turned sideways.
All test on this page are done with the power on and all plugs connected. Be conscientious! Apparatus-repair-it.com is not responsible for any impairment or injuries! See disclaimer
Evaporator Fan
(The fan inside the freezer)
If the evaporator fan isn't running, the fan or the primary board could be the problem. The section of the refrigerator fan motor diagnostics page will describe how to find out if you need to modify the fan, chief lath or both.
First thing you lot should do is open the door of the refrigerator for more than than 3 minutes. Afterward three minutes the refrigerator will enter a liner protection mode, which volition turn the fan on. If the fan doesn't come on you lot volition need to determine if the fan or the lath is bad. Leave the door open to ensure the fan should exist running during testing. Also go out all plugs connected even the J2 plug at which you lot will be testing. To test this, locate the main board on the back of the fridge. On that board there is plug marked J2, this is where testing for the fan is done. Set your meter to read DC voltage and place your black (common) atomic number 82 on J2-pin iii (3rd pin from left) and your cerise lead on J2 pin 8 and you should get 12-14 VDC and if you don't supersede the main board.
Adjacent leave your black pb on the aforementioned wire and test to pin 4 this pivot should read 12 VDC. Annotation that if the fridge isn't in liner protection fashion y'all may get 8VDC and on some models you may fifty-fifty get 4VDC, this just ways that the fan is on depression or medium speed mode at the time of testing.
If the voltage is correct and the fan isn't running replace the fridge fan motor. If the voltage isn't correct replace the board. This refrigerator fan motor tin be purchased at AppliancePartsPros.com As well as the lath.
Condenser Fan
(The fan beside the compressor)
Note some electronic board models have condenser motors that run off of 110V Air-conditioning. If yours does yous cannot check the motor from the board using the method described beneath. This section is only for models with DC condenser fan motors. The DC motors are fully enclosed and are normally white (ceramic). The 110 V AC motors are metal with exposed copper coils.
The condenser fan is the fan located near the compressor and information technology should be running anytime the compressor is running. This section of the refrigerator fan motor diagnostics guide will hash out how to test the condenser fan on GE electronic refrigerators. If the compressor is running but the fan isn't more than likely the fan is bad but it could be the board. Leave all plugs connected fifty-fifty the J2 plug at which you volition be testing.
To exam this, locate the principal board on the back of the refrigerator. On that board there is a plug marked J2, this is where testing for the fan is done. Set your meter to read DC voltage and place your black (mutual) lead on J2-pin 3 (third pin from left) and your red lead on J2 pin eight you should get 12-fourteen VDC and if you don't replace the chief lath.
Next, leave your black lead on the aforementioned wire and test to pin 5 this pin should read 12 VDC, 8VDC, or 4VDC. Note that you should only go 4VDC if your refrigerator has a variable speed compressor.
If the voltage is right and the fan isn't running replace the fan. If the voltage isn't correct replace the board. This refrigerator fan motor tin can be purchased at AppliancePartsPros.com As well as the board.
Fresh Food Fan
(fan within fresh food department)
Some GE electronic refrigerators have a fresh food refrigerator fan motor and if the fresh food fan isn't operating the efficiency of the refrigerator volition suffer. The fresh food fan is located inside the air duct in the dorsum top of the fresh food section. To access the fan you will have to remove all the shelves in the fresh food section and remove the air-duct in the back of the refrigerator. Once washed you should exist able to remove the duct that holds the fresh food fan. Note that while y'all are at that place, check to make certain the damper inside that duct is closed. Information technology should be closed being that the door has been opened for more than three minutes while y'all removed the duct. If it isn't closed replace it. It will come with the entire duct, which includes the fan. If the fan will not run, the problem could be the fan or the main board.
Go out all plugs connected even the J2 plug at which you volition be testing. To test this, locate the chief board on the back of the fridge. On that board in that location is a plug marked J2 this is where testing for the fan is washed. Ready your meter to read DC voltage and place your black (common) lead on J2-pin 3 (third pin from left) and your cherry lead on J2 pivot eight and yous should get 12-14 VDC and if you don't replace the master lath.
Adjacent examination betwixt pin 6 and pin viii. You should get at to the lowest degree 8 volts DC. If voltage is present but the fan isn't running replace the fan and if there isn't voltage replace the lath. This refrigerator fan motor can exist purchased at AppliancePartsPros.com As well every bit the lath.
Fresh Nutrient Evaporator For Dual Evaporator Models
(not talked nearly in the video)
Some GE side-past-side refrigerators utilize a dual evaporator organization. This is sometimes chosen the climateKeeper system. On these models at that place is an evaporator fan for the fresh food section. This is not the same as the fresh food fan talked nearly to a higher place. Testing for this fan is done on the same pins only the voltage volition be different. Follow the instructions below for testing this fan motor. If you have a dual evaporator model and you demand to check the fresh food evaporator fan delight refer to this folio.
Fresh Food Non Cooling On GE Dual Evaporator Refrigerators
Noisy Fan Motor
This department of the GE refrigerator fan motor page talks about noisy fan motors on GE electronic refrigerators. Typically if the fan motors on these refrigerators are noisy it is because the main lath is bad. A bad main lath tin cause the fan to rapidly change speeds, cause the fan to groan, or make it sound like the fan is straining. Rapid speed changes are a expressionless give abroad for the main board being bad. The fans do alter speeds only the speed should gradually change. But a bad fan motor or the main board can cause the other two noises. The main lath is most likely but tin can exist hard to make up one's mind. Return From GE Refrigerator Fan Motor Diagnostics
How To Check If My Refrigerator Was Registered In Ge,
Source: http://www.appliance-repair-it.com/refrigerator-fan-motor.html
Posted by: preeceanstating.blogspot.com

0 Response to "How To Check If My Refrigerator Was Registered In Ge"
Post a Comment